I am trying to program a Delta DVP12SE PLC to run a PID loop, but the controller doesn't respond correctly. I need an experienced user to point me on what am I doing wrong.
ID Proyek: 17610837

Tentang proyek

5 proposal
Proyek remot
Aktif 6 tahun yang lalu

Ingin menghasilkan uang?

Keuntungan menawar di Freelancer

Tentukan anggaran dan garis waktu Anda
Dapatkan bayaran atas pekerjaan Anda
Uraikan proposal Anda
Gratis mendaftar dan menawar pekerjaan
Diberikan kepada:
Avatar Pengguna
Dear client, My name is Gonzalo Viarengo and I have more than 15 years of experience in designing and programming automation devices. Regarding your project I have to admit tha delta PID loops are very confusing to configure at the beggininig but I will guide you how to do it in less than a day. Some information I need from you: - What kind of process variable are you trying to controlling to. - What MV (actuator) are using to control the PV. - Are you trying to auto-tune you loop? I'm new at [login to view URL] but I have an extensively experience in [login to view URL] and I have a complete portofolio in LinkedIn you can check in the following link: [login to view URL] Also I'm spanish fluent so If you are from Salvador, we can communicate in spanish. I would love the opportunity to talk with you about your issue and what I might bring to it. Please let me know a time that works best for you and I will make myself available. Thank you for your time and consideration.
$15 USD dalam 1 hari
5,0 (3 ulasan)
2,5
2,5
5 freelancer menawar dengan rata-rata $23 USD untuk pekerjaan ini
Avatar Pengguna
Good Experience in PID Loop
$25 USD dalam 2 hari
0,0 (0 ulasan)
0,0
0,0
Avatar Pengguna
First off exactly what kind of PLC do you have? When I look at the catalog for the DVP12SE(R/T) it does not have any analog I/O - just 8 digital inputs and 4 digital outputs. I assume you know PID means proportional integral derivative and is basically a mathematical method based on the classical spring and damper. It usually needs an analog (or variable) input and an analog (variable) output. As far as I know the DVP12ES does not have that capability and therefore cant run PID. From what I know the DVP slim lines were either a copy of the NAIS or based on the NAIS PLCs. The NAIS (which I have used - long time ago) were expandable and could have analog in the expansions and could then run PID. I need to know more about what you are doing to help you. What is the type of process you are trying to control? Is it temperature, pressure, flow, level or something else? What type of sensor are you using for the input? What type of device are you using for the control? Is the control output analog or digital PWM? Basically - what are you trying to do?
$30 USD dalam 1 hari
0,0 (0 ulasan)
0,0
0,0

Tentang klien

Bendera EL SALVADOR
CIUDAD MERLIOT, El Salvador
5,0
13
Memverifikasi Metode pembayaran
Anggota sejak Mar 17, 2009

Verifikasi Klien

Terima kasih! Kami telah mengirim Anda email untuk mengklaim kredit gratis Anda.
Anda sesuatu yang salah saat mengirimkan Anda email. Silakan coba lagi.
Pengguna Terdaftar Total Pekerjaan Terpasang
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
Memuat pratinjau
Izin diberikan untuk Geolokasi.
Sesi login Anda telah kedaluwarsa dan Anda sudah keluar. Silakan login kembali.